home *** CD-ROM | disk | FTP | other *** search
/ Atari Mega Archive 2 / Atari Mega Archive CD - Volume 2.iso / telecomm / upgrade.txt < prev    next >
Text File  |  1995-04-22  |  20KB  |  454 lines

  1.                    STalker™ 3.01 to 3.02 Patch Program
  2.  
  3.             This program will upgrade STalker version 3.01 to
  4.             version 3.02.  It will ONLY upgrade version 3.01.
  5.  
  6.   This program is copyright © 1992 by Gribnif Software.  All rights are
  7.   reserved.  This program may be freely distributed to all legitimate
  8.   registered users of STalker 3.
  9.  
  10.   Any questions or comments, please contact us at:
  11.  
  12.       Gribnif Software, P.O. Box 350, Hadley, MA 01035, USA
  13.       Tel: (413) 584-7887, Fax: (413) 584-2565
  14.       GEnie: GRIBNIF
  15.  
  16.  
  17. What is needed to upgrade
  18. =========================
  19.  
  20.   1.  An un-modified, registered, STalker 3 Master Disk, version 3.01.
  21.  
  22.   2.  A hard disk or a blank formatted floppy disk (to place the PATCH302.PRG
  23.       and PATCH302.DAT on).
  24.  
  25.  
  26. How to upgrade your STalker version 3.01 to version 3.02
  27. =========================================================
  28.  
  29.   1.  Make sure you have made a backup copy of the STalker 3 Master Disk.
  30.  
  31.   2.  Place the PATCH302.PRG and PATCH302.DAT on your hard disk or on the
  32.       blank floppy disk (it may need the extra disk space to write some
  33.       temporary files, depending on free memory.)
  34.  
  35.   3.  Run the PATCH302.PRG and follow the on-screen prompts.
  36.  
  37.   4.  Once you have finished upgrading your master disk to version 3.02, make
  38.       a backup copy of this newer version.
  39.  
  40.   ** VERY IMPORTANT STEP, READ CAREFULLY **
  41.  
  42.   5.  To install the newer version on your system, you MUST replace the
  43.       following STalker 3.01 files in your system with the 3.02 version files
  44.       from the newly upgraded disk:
  45.       
  46.       \STALKER.ACC
  47.       \STALKER.PRG
  48.       \STALKER.RSC
  49.       \BACKTALK\BACKTALK.PRG
  50.       \BACKTALK\SCRIPTS\PREFIX.BTS
  51.       \BACKTALK\SCRIPTS\PREFIX.BTK
  52.       \BACKTALK\SCRIPTS\STALKER.BTH
  53.  
  54.       These files were also included with the patch program. They should be
  55.       copied as well:
  56.  
  57.       \BACKTALK\SCRIPTS\BPLUS.BTS
  58.       \BACKTALK\SCRIPTS\BPLUS.BTK
  59.       \BACKTALK\SCRIPTS\BPLUS.TTP
  60.       
  61.  
  62. If you get an error message
  63. ===========================
  64.  
  65.   If your STalker 3 Master Disk has been modified in any way (including moving
  66.   files around), the patch program will not be able to perform the upgrade.
  67.   You will get an error message indicating that this has happened.  In this
  68.   case, you should mail us the disk so that we can upgrade it.
  69.  
  70.   To have your disk upgraded by us, you need to:
  71.  
  72.   1.  Send in your original, registered, STalker 3.01 Master Disk.
  73.   2.  Enclose a U.S. check for $5 + $2 shipping & handling ($7 total).
  74.   3.  Enclose a note with your name, address, and daytime phone number.
  75.  
  76.   In return you will receive the upgraded 3.02 Master Disk. If you have
  77.   already purchased this patch disk from us for $5, please just include your
  78.   original disk and $2.
  79.  
  80.  
  81. Helpful Hints
  82. =============
  83.  
  84.   o If you are having trouble with lost characters, the very first thing
  85.     to do is try running AUXINIT.PRG.
  86.  
  87.   o When using high speed modems (9600 baud or greater) you will have to
  88.     use hardware (RTS/CTS) flow control, rather than XON/XOFF flow control.
  89.     Several pointers:
  90.  
  91.     o Make sure STalker has been configured for RTS/CTS in the Port Settings
  92.       dialog for each service you plan to connect to at high speed.
  93.     o Make sure your modem is configured for RTS/CTS. This varies from modem
  94.       to modem; some use an AT command, others a DIP switch. Consult your
  95.       modem's manual for more information.
  96.     o Run the appropriate combination of patch programs. These can be found
  97.       in the EXTRAS folder of your STalker disk:
  98.       
  99.       TOS version        Port                Program(s)
  100.        1.0-1.6x      ST-compatible      SERIALFX
  101.        2.00-2.05     ST-compatible      SERIALFX and SERIALFX
  102.                      other              SERPTCH
  103.        2.06          ST-compatible      SERIALFX
  104.                      other              none needed
  105.        3.00-3.05     ST-compatible      SERIALFX and SERIALFX
  106.                      other              SERPTCH
  107.        3.06          ST-compatible      SERIALFX
  108.                      other              none needed
  109.  
  110.   o If, after dialing a service, you notice that you cannot access any of
  111.     STalker's functions and the "Dial" menu title is still selected, then
  112.     this most likely means that there is a problem with your autologin
  113.     sequence for that service. Press Undo to cancel the autologin and then
  114.     check the appropriate entry in the Autodialer Directory.
  115.  
  116.  
  117. Changes for STalker 3.02 - Jun. 7th 1992
  118. ========================================
  119.  
  120. This version contains the following enhancements:
  121. ................................................
  122.  
  123. - A new protocol setting was added: "CIS B-Plus".  If the protocol is set to
  124.   B-Plus, STalker will respond to the CompuServe initiation character by
  125.   attempting to invoke a script called BPLUS from the script directory.
  126.   Enclosed with this new version of STalker is a BPLUS.BTK, which simply runs
  127.   BPLUS.TTP (the actual file transfer program). BPLUS.TTP must reside in the
  128.   script directory in order for this feature to work.
  129.  
  130. - Baud rates greater than 19,200 are now supported on the MSTe/TT Serial 2 and
  131.   Modem 2 ports.  Due to the way the hardware works, the extra speeds aren't
  132.   the same between the two ports.  Serial 2 has the normal progression of
  133.   speeds: 38400, 57600, 115200, and 230400.  Modem 2 is a bit odd though:
  134.   38400, 76800, and 153600.
  135.  
  136.   While testing these between a TT and a PC, the system was usually getting a
  137.   maximum ZModem throughput of just over 4100 cps.  A system with TT-RAM may
  138.   do a little better, but it should be pointed out that it's not realistic to
  139.   expect to get close to 100% efficiency once you go higher than 38400.
  140.  
  141. - Capture and Printer status are now reflected in the window title.  If
  142.   Capture is on, a black dot appears to the left of the window title text
  143.   where a space would normally be.  Similarly, if the Printer is on, a dot
  144.   appears to the right of the text.
  145.  
  146. - The limit on the number of lines in the scroll-back buffer has been
  147.   increased to 9999.  Unless you've got a very fast machine, at some point the
  148.   number of lines may start to make a noticeable decrease in scrolling speed,
  149.   as the buffer fills up.
  150.  
  151. - The Terminal settings dialog now has a "Swap Backspace & Delete" option for
  152.   VT100/PC-ANSI emulations.  If you use a VAX with VMS, you've probably been
  153.   wishing for this since VMS uses Delete the way most other systems use
  154.   Backspace.
  155.  
  156. - The speed of scrolling in a VT100 / PC-ANSI scrolling region has been
  157.   significantly improved.  This new method will only be used, however, if
  158.   STalker's window is on top or is not obscured by another window.
  159.  
  160. - The path for the "Open configuration..." and "Save configuration as..."
  161.   commands is now remembered, although it doesn't get saved with the
  162.   configuration.  STalker will remember any changes you make to either path
  163.   for the rest of the session, and the upload path will not be affected.
  164.  
  165. - Older versions of STalker would put the menu bar inside the window if you
  166.   held down the Alt key while launching them as a .PRG.  Since this could be
  167.   done by accident, it has been removed for the new version. If you really want
  168.   to have the menu bar inside the window, you can give STalker "-m" or "-M" as
  169.   the first parameter in its command line.
  170.  
  171. - Control+Keypad can now be used as an alternative to Alt+Keypad to run
  172.   scripts.  TOS 2.06/3.06 intercepts Alt+KeypadDigit keystrokes, which made it
  173.   impossible to invoke scripts in that fashion.
  174.  
  175. - The '@' character can now be used in logon strings and other dialogs.  The
  176.   GEM dialog handler treats the '@' character in a special way if it is the
  177.   first character of an editable field - it makes the entire field empty (try
  178.   it with any GEM program!).  To get around this, the '@' character is mapped
  179.   to one of the Hebrew characters that vaguely resembles an @, 'פ' to be
  180.   specific (hex D2).  STalker then translates this Hebrew character to the '@'
  181.   character when the setting is used in